Skip to main content
. Author manuscript; available in PMC: 2013 Aug 14.
Published in final edited form as: AJR Am J Roentgenol. 2013 Jul;201(1):142–146. doi: 10.2214/AJR.12.9181

TABLE 3.

Normalized Organ Doses for an Average National Lung Screening Trial Participant (Body Mass Index, 27.3)

Organ Ratio of Organ Dose to Effective Dose (mGy/mSv)

Spine, thoracic 7.21
Scapulae 6.76
Ribs 6.04
Adrenal glands 3.59
Kidneys 3.17
Spine, lumbar 2.98
Spleen 2.91
Lungs 2.84
Esophagus 1.73
Pancreas 1.69