Skip to main content
. 2013 Mar;20(2):17–24.

Table 3.

Simple regression norms for the prediction of pulmonary function measurements from age and body height in the studied population

Pulmonary Function Measurement Regression Equation R R2 SEE
VC (l) VC = 0.206 A – 0.3558 0.75 0.56 0.38
FVC (l) FVC = 0.179 A – 0.0186 0.69 0.48 0.39
FEV1 (l) FEV1 = 0.219 A – 1.2328 0.71 0.50 0.46
FEV1% (%) FEV1% = 1.452 A + 59.106 0.42 0.18 6.74
PEFR (l.min-1) PEFR = 19.57 A + 252.78 0.60 0.36 55.61
VC (l) VC = 0.087 H – 10.45 0.89 0.79 0.27
FVC (l) FVC = 0.077 H – 9.03 0.84 0.70 0.30
FEV1 (l) FEV1 = 0.096 H – 12.48 0.87 0.76 0.33
FEV1% (%) FEV1% = 0.702 H – 26.78 0.57 0.32 6.12
PEFR (l.min-1) PEFR = 10.287 H – 1142.10 0.88 0.77 32.63

Abbreviation: A = Age, H = Body height, SEE = standard error of estimate.