Table 1.

Comparison of mixing performance and mixing efficiency per mm mixing path length, at Re = 70, evaluated numerically in SeLMA and a selection of micromixers adapted from literature: the Archimedes spiral [19], the Meandering-S [18], and a T-Channel.

Micromixer η (%)
ηL(%/mm)
SeLMA 87.015 6.8911
Meandering-S 72.31 6.02
Archimedes 63.80 5.32
T-Channel 19.11 1.59