Table 3.
Patient | Anti-HE4 antibodies (mean OD) # | HE4 antigen (pM) | ||
---|---|---|---|---|
Dilution 1:20 | Dilution 1:100 | Serum | Urine | |
1 | 0.63 | 0.57 | 439* | 11.5* |
2 | 0.29 | 0.18 | 180* | 11.9* |
3 | 0.03 | 0 | 116 | 7.0* |
4 | 3.51* | 3.65* | 90 | 9.1* |
5 | 1.70* | 2.61* | 652* | 16.9* |
6 | 0.01 | 0.09 | 665* | 46.4* |
7 | 0.10 | 0.21 | 492* | 15.6* |
8 | 0.30 | 0.16 | 71 | 1.5 |
9 | 0.65 | 0.39 | 73 | 2.2* |
10 | 2.69* | 1.38* | 176* | 8.1* |
11 | 0.30 | 0.23 | 337* | 4.9* |
12 | 0 | 0 | 82 | 1.7 |
13 | 2.49* | 2.93* | 205* | 2.2* |
Cut-off values were the same as for the data presented in Table 2 and adsorption values corresponding to M+2 SD are indicated (*).
Sera were scored as positive for HE4 antigen using the 150 cutoff established for the FDI kit. Urine samples were assayed as described [42] and scored as positive (M+2SD) at a cut-off value of 2.0.