Skip to main content
. 2013 Aug 5;2013:841217. doi: 10.1155/2013/841217

Table 2.

Steep suction procedure. Median values of parameters defining the creep extension in the repeat stress-versus-time recording modality (3 and 5 cycles) for different probe aperture diameters (AD 2 mm and AD 4 mm) using a 500 mbar depression for 5 s performed with (w) and without (w/o) outer contention on normal skin and connective tissue disorders. The differences in maximum deformation after 3 and 5 cycles (ΔMD3, and ΔMD5, and the corresponding residual deformations (ΔRD3 and ΔRD5) were recorded.

Skin condition ΔMD3 (%) ΔMD5 (%) ΔRD3 (%) ΔRD5 (%)
AD 2 mm AD 4 mm AD 2 mm AD 4 mm AD 2 mm AD 4 mm AD 2 mm AD 4 mm
w w/o w w/o w w/o w w/o w w/o w w/o w w/o w w/o
Normal 3 3 5 5 4 5 7 5 5 6 6 6 6 6 7 7
Scleroderma 1 1 2 2 1 1 2 2 2 2 3 4 3 4 3 4
Ehlers-Danlos 1 1 1 2 3 4 5 5 3 4 5 5 4 5 5 5
Dermatoporosis 1 1 4 5 2 2 4 5 2 2 4 5 5 5 9 5
Acromegaly 2 2 5 3 2 2 2 2 2 2 5 4 2 3 2 3