Skip to main content
. 2013 Jul 10;89(1):11–15. doi: 10.4269/ajtmh.13-0089

Table 3.

Comparison of results obtained with the BinaxNOW Filariasis card test and the Alere Filariasis Test Strip with blood samples collected in Liberia

Card test result Test strip result
Positive Negative Positive (%)
Positive (N = 98) 97 1 99.0
Negative (N = 405) 27 378 6.0
Total (% positive) 124 (78.2%) 379 (0.3%)

Results presented are for 503 blood samples, with valid results for both tests.