Table 1.
Label input data | |||
---|---|---|---|
Flux name | Cumomer Index | Value | STD |
GLC | #000000 | 0.445 | - |
#100000 | 0.500 | - | |
#000001 | 0.011 | - | |
#000010 | 0.011 | - | |
#000100 | 0.011 | - | |
#001000 | 0.011 | - | |
#010000 | 0.011 | - | |
Rul5P | #1xxxx | 0.1979 | 0.002 |
#x1xxx | 0.0153 | 0.002 | |
#xx1xx | 0.0284 | 0.002 | |
#xxx1x | 0.0122 | 0.002 | |
#xxxx1 | 0.0976 | 0.002 | |
Ery4P | #1xxx | 0.0568 | 0.002 |
#x1xx | 0.0229 | 0.002 | |
#xx1x | 0.0118 | 0.002 | |
#xxx1 | 0.0704 | 0.002 | |
GA3P | #1xx | 0.0330 | 0.002 |
#x1x | 0.0126 | 0.002 | |
#xx1 | 0.1207 | 0.002 | |
PEP | #1xx | 0.0330 | 0.002 |
#x1x | 0.0126 | 0.002 | |
#xx1 | 0.1207 | 0.002 |
Values are taken from the example input file included in the 13CFLUX demo. Substrate enrichment values are considered as constants.