Table 2.

Predicted RNTCP values for cardiac structures for the MB patient using combinations of NTCP model parameters (min: D50= 40 Gy, n= 1, m= 0.05; max: D50= 80 Gy, n= 0.2, m= 0.5), the myocardium (min: D50= 40 Gy, γ= 1.5, s= 0.5; max: D50= 80 Gy, γ= 0.8, s= 1), and the whole heart (min: D50= 40 Gy, γ= 1.5, s= 0.5; max: D50= 80 Gy, γ= 0.8, s= 1)

Structure
RNTCP
  Minimum Baseline Maximum
Pericardium
0
1.43 × 10-5
0.57
Myocardium
0
0.03
0.19
Whole heart 0 0.03 0.18