Skip to main content
. 2013 Jan 30;33(5):2060–2070. doi: 10.1523/JNEUROSCI.4012-12.2013

Table 3.

Number and diameter of myelinated and unmyelinated fibers in the saphenous nerve of WT and NRTN-OE mice

No./diameter/thicknessa WT NRTN-OE
No. of myelinated axons 556.25 ± 14.64 550.5 ± 21.17
No. of unmyelinated axons 2472.25 ± 83.78 2430.25 ± 44.95
Diameter of myelinated axons (μm) 3.64 ± 0.11 3.92 ± 0.23*
Diameter of unmyelinated axons (μm) 0.86 ± 0.04 1.12 ± 0.05*
Myelin thickness (μm) 0.65 ± 0.03 0.70 ± 0.03

aThe number of myelinated and unmyelinated axons in the saphenous nerve was unchanged in NRTN-OE mice. However, the average diameter of both populations was increased. Myelin thickness was unchanged.

*NRTN-OE > WT (p < 0.05; t test).