Commercially available bioengineered liver models

Company Platform Dimensionality Mimicked biomimetic cues
Hepregen Micropatterned liver cells colonies surrounded by stromal cells 2D Hepatocyte–stromal cells interaction
Miromatrix Liver constructs based on whole-organ decellularization–recellularization 3D Vascularization, liver-specific ECM, hepatocyte–stromal cells interaction
MIT (Griffith laboratory) Microfluidic system. 3D Physiological shear stress.
CellAsic Microfluidic system 2D Plasma perfusion, endothelial-like barrier between liver cell layers (artificial sinusoids)
Hurel Microfluidic system 2D Plasma perfusion, liver architecture.
RegeneMed Porous nylon 3D interweaving nanofiber scaffold, 96-well format 3D 3D hepatocyte–stromal cells interaction
InSphero Spheroid model 3D 3D hepatocyte–Kupffer cell–endothelial cell interactions