Table 5.

Accuracy comparison between the harmonic motion and shear building tests.

Testing Frequency (Hz) Amplitude (mm) Difference Measure
Harmonic Motion (from Table 3) 2 2 3.4%
Shear Building 1.98 1.96 6.2%
(lowest frequency) (standard deviation)