Skip to main content
. 2012 Apr 30;53(4):2382–2389. doi: 10.1167/iovs.11-7951

Table 4.

pAUROCs for Classifying Eyes as Progressed or Stable at Baseline for All Techniques/Parameters when pAUROC > 0.75 Specificity and pAUROC > 0.85 Specificity

Technique
pAUROC > 0.75 Specificity (95% CI)
pAUROC > 0.85 Specificity (95% CI)
HRT GPS 0.033 (0.000–0.091) 0.014 (0.000–0.045)
SAP MD 0.031 (0.000–0.084) 0.009 (0.000–0.036)
SAP PSD 0.062 (0.001–0.124) 0.025 (0.000–0.064)
RVM using all HRT parameters (117 features) 0.048 (0.001–0.106) 0.013 (0.000–0.049)
RVM using optimized set of HRT parameters (8 features) 0.060 (0.001–0.125) 0.022 (0.000–0.059)
RVM using all SAP TD parameters (52 features) 0.062 (0.000–0.127) 0.020 (0.000–0.060)
RVM using optimized set of SAP TD parameters (23 features) 0.101 (0.033–0.169) 0.044 (0.000–0.091)
RVM using all HRT and SAP TD parameters (169 features) 0.065 (0.003–0.125) 0.026 (0.000–0.062)
RVM using optimized set of HRT and SAP TD parameters (28 features) 0.126 (0.056–0.196) 0.055 (0.003–0.108)