Skip to main content
. 2010 Mar 1;41(1):164–172. doi: 10.1590/S1517-838220100001000024

Table 2.

Central composite design (CCD) matrix of independent variables in with their corresponding response by experiments and predicted.

Run A B C D Lovastatin yielda (µg g-1 DFM)
% Moisture content Particle size (mm) K2HPO4 (% v/w) Trace ion conc. (% v/w) Experimental Predicted
1 60 0.35 10 10 2206 ± 51 2532
2 80 0.35 10 10 1743 ± 21 1916
3 60 0.7 10 10 1721 ± 43 1736
4 80 0.7 10 10 1203 ± 34 1353
5 60 0.35 30 10 2322 ± 51 2248
6 80 0.35 30 10 1633 ± 14 1941
7 60 0.7 30 10 989 ± 54 1238
8 80 0.7 30 10 1187 ± 23 1164
9 60 0.35 10 30 2563 ± 39 2632
10 80 0.35 10 30 1539 ± 45 1681
11 60 0.7 10 30 2076 ± 44 2159
12 80 0.7 10 30 1322 ± 60 1442
13 60 0.35 30 30 2506 ± 21 2747
14 80 0.35 30 30 2075±35 2106
15 60 0.7 30 30 2187 ± 31 2061
16 80 0.7 30 30 1587 ± 22 1652
17 50 0.525 20 20 1196 ± 47 1023
18 90 0.525 20 20 263 ± 21 262
19 70 0.175 20 20 2914 ± 54 2525
20 70 0.875 20 20 1324 ± 26 1276
21 70 0.525 0 20 3071 ± 45 2751
22 70 0.525 40 20 2795 ± 37 2678
23 70 0.525 20 0 2577 ± 17 2233
24 70 0.525 20 40 2914 ± 30 2821
25 70 0.525 20 20 2593 ± 46 2472
26 70 0.525 20 20 2501 ± 19 2472
27 70 0.525 20 20 2451 ± 61 2472
28 70 0.525 20 20 2435 ± 46 2472
29 70 0.525 20 20 2435 ± 26 2472
30 70 0.525 20 20 2443 ± 43 2472
a

Values are mean ± SD of three or more determinations