Skip to main content
. Author manuscript; available in PMC: 2014 Oct 1.
Published in final edited form as: Accid Anal Prev. 2013 Jul 16;59:537–547. doi: 10.1016/j.aap.2013.06.037

Table 6.

A values (the area under the one-point ROC) for vision,cognitive and attention measures as well as test batteries (“models”)

Test Specificity Sensitivity AUC Aa
Vision Tests
 Visual Acuity .41 .78 .52 .66
 Contrast Sensitivity .43 .93 .65 .80
Cognitive Tests
 MMSE .76 .67 .68 .78
 MoCA .68 .80 .78 .81
 Trail Making Tasks
  Part A .93 .39 .64 .79
  Part B .67 .75 .72 .77
Attention Tests
 MOT .86 .44 .60 .75
 UFOV Tasks
  Subtest 1 .79 .50 .66 .72
  Subtest 2 .72 .93 .84 .89
Batteries
 Clinical Model 1.00 .50 .79 .88
 MoCA Model .91 .60 .73 .84
 MOT Model .82 .79 .79 .86
 Improved Model .95 .80 .91 .93
a

A values were calculated using the optimal specificity and sensitivity values from Table 4 (individual tests) and Table 5 (models).