Skip to main content
. 2013 Jun 24;4(2):130–133. doi: 10.1016/j.jcdr.2012.06.001

Table 2.

Spirometry and impulse oscillometry findings in patient and control groups.

Patients
(n = 24)
Controls
(n = 24)
P-value
FEV1 (L/min) 2.26 ± 0.68 3.09 ± 0.82 0.01
FVC (L) 2.55 ± 0.86 3.32 ± 0.87 0.04
R5 Hz (kPa/(L/s)) 0.37 ± 0.21 0.27 ± 0.09 0.06
R2O Hz (kPa/(L/s)) 0.26 ± 0.10 0.24 ± 0.08 0.39
X5 Hz (kPa/(L/s)) −0.20 ± 0.13 −0.13 ± 0.08 0.05
X2O Hz (kPa/(L/s)) −0.04 ± 0.02 −0.04 ± 0.02 0.28
Z (kPa/(L/s)) 0.43 ± 0.22 0.31 ± 0.09 0.03

Values are means ± SD; FEV1, forced expiratory volume in 1 second; FVC, forced vital capacity; R5 Hz, resistance at 5 Hz; R2O Hz, resistance at 20 Hz; X5 Hz, reactance at 5 Hz; X2O Hz, reactance at 20 Hz; Z, impedance of the respiratory system at 5 Hz.