Skip to main content
. 2013 Sep 2;7:1761–1769. doi: 10.2147/OPTH.S49375

Table 2.

Baseline macular SD-OCT characteristics

All (n = 40)
ERM (n = 21)
MH (n = 14)
VO (n = 5)
SE FE SE FE SE FE SE FE
Central (μm) 390 ± 105 258 ± 29* 404 ± 99 265 ± 31* 414 ± 105 243 ± 25* 263 ± 18 263 ± 11
Superior (μm) 375 ± 69 317 ± 24* 389 ± 60 324 ± 25* 376 ± 84 306 ± 24* 314 ± 16 312 ± 6
Nasal (μm) 379 ± 69 313 ± 23* 383 ± 69 318 ± 17* 396 ± 71 304 ± 33* 317 ± 19 317 ± 10
Inferior (μm) 372 ± 75 311 ± 24* 383 ± 76 319 ± 22* 379 ± 78 300 ± 26* 309 ± 19 310 ± 9
Temporal (μm) 370 ± 78 312 ± 28* 387 ± 72 320 ± 31* 365 ± 93 301 ± 22* 308 ± 16 309 ± 14
Cube volume (mm3) 11 ± 1 10 ± 1* 11 ± 1 10 ± 1* 11 ± 2 9.9 ± 1 9.9 ± 1 9.9 ± 0.4

Note:

*

P < 0.05 between study and fellow eyes.

Abbreviations: SD-OCT, spectral-domain optical coherence tomgraphy; ERM, epiretinal membrane; MH, macular hole; VO, vitreous opacities; SE, study eye; FE, fellow eye.