Skip to main content
. 2012 Nov 30;304(3):H406–H414. doi: 10.1152/ajpheart.00672.2012

Fig. 1.

Fig. 1.

Myocardial oxygen consumption (MVO2) during extracorporeal membrane oxygenation (ECMO; n = 5). MVO2 (A) was determined through coronary sinus flow measurement (B) and systemic and coronary sinus blood sampling for O2 content (C). ECMO decreases MVO2 due to drop in A-V O2 content difference. *P < 0.05 compared with pre (baseline before ECMO).