Skip to main content
. 2013 Nov 15;82:470–480. doi: 10.1016/j.neuroimage.2013.06.013

Table 1.

Relevant LBC1936 MRI sequences and their parameters. The complete LBC1936 MRI protocol is described in Wardlaw et al. (2011).

Sequence IR-prep FGRE (3D) FSE (2D) GRASS (2D)
Contrast type T1-weighted T2-weighted T2*-weighted
FOV in mm2 256 × 256 256 × 256 256 × 256
Orientation Coronal Axial Axial
Slice thickness in mm 1.3 2 2
Acquisition matrix 256 × 256a 256 × 256 256 × 256a
Flip angle in degrees 8 20
TI/TE/TR in ms 500/4/9.8 –/102/11,320 –/15/940
Bandwidth in kHz 15.63 20.83 12.5
a

After interpolation by the scanner software.