Skip to main content
. 2013 Jul 3;11:14. doi: 10.1186/2052-336X-11-14

Table 1.

Different parameters for the NOMs removal using CNTs in a fixed-bed adsorption column for different operating conditions

CNTs types
Initial NOMs concentration (mg/L)
Break point time parameters
Saturation point time parameters
    Vbp, mL tbp, min qbp, mg/g Vsat, mL tsat, h qsat, mg/g
MWCNT
10
2400
480
23.58
9000
1800
53.46
5
3300
660
16.32
9900
1980
30.40
3
4500
900
13.39
12300
2460
24.75
SWCNT
10
3600
720
35.64
10500
2100
66.24
5
6000
1200
29.82
11700
2340
40.63
  3 10200 1380 27.96 15300 3060 29.77

Vbp and Vsat: volumes of treated water up to breakthrough point time and saturation point time respectively.

tbp and tsat: Breakpoint time and saturation point time respectively.

qbp and qsat: adsorption capacities in breakpoint time and saturation point time respectively.