Table 5. Differences of delineation of clinical target volume (CTV, for CTV2) in intensity-modulated radiotherapy for NPC in different cancer centers.

Region RTOG0615[23] Singapore[4] Hong Kong[3] Fuzhou[5] Chinese guideline[22]
Nasal cavity Posterior 1/4–1/3 Posterior 1/3 Posterior 1/3 5 mm anterior to the posterior nasal aperture Posterior part
Maxillary sinus Posterior 1/4–1/3 Posterior 1/3 Posterior 1/3 5 mm anterior to the maxillary mucosa 5 mm anterior to the maxillary mucosa
Clivus Anterior 1/2–2/3 (entire if involved) Anterior 1/2 (entire if involved) Anterior 1/2 (entire if involved) Anterior 1/3 Anterior 1/3
Foramen ovale Bilaterally Bilaterally Bilaterally Bilaterally
Sphenoid sinus Inferior part (entire in T3–T4 disease) Included Included Inferior part (entire if involved) Inferior wall/basis
Cavernous sinus Included in high-risk patients (T3, T4, bulky disease involving the roof of the nasopharynx) Included Included Inferior part
Retropharyngeal lymph node Bilaterally (skull base to cranial edge of the hyoid) Bilaterally (skull base to the level of the hyoid) Bilaterally (skull base to the bottom of the hyoid) Bilaterally (skull base to cranial edge of C2) Bilaterally (skull base to caudal edge of C2)
Levels II–V Bilaterally Bilaterally Electively irradiated Bilaterally Electively irradiated
Level Ib Bilaterally included in node-positive patients Included if the ipsilateral neck involved Electively irradiated Electively irradiated