Table 2:

Aortic annulus and fusion data of 19 cf-LVAD patients

Patient (no.) AAd (mm) LC and RC fusion (mm) LC and NC fusion (mm) RC and NC fusion (mm) Max fusion (mm) Total fusion (mm) No. of fused commissures (>3 mm) Residual lumen (mm)a
1 25 0 0 2 2 2 0
2 22 0 5 6 6 11 2
3 21 14 0 5 14 19 2
4 25 0 3 0 3 3 0
5 22 0 0 1 1 1 0
6 22 0 0 5 5 5 1
7 15 1 0 10 10 11 1
8 n/a 0 0 0 0 0 0
9 25 4 6 2 6 12 2
10 24 0 0 0 0 0 0
11 21 0 10 10 10 20 2
12 22 0 9 5 9 14 2
13 28 2 2 2 2 6 0
14 28 1 3 3 3 7 0
15 23 14 15 15 15 44 3 4
16 24 10 10 14 14 34 3 4
17 22 2 0 2 2 4 0
18 20 9 9 11 11 29 3 3
19 22 10 10 11 11 31 3 8
23 ± 3b 1 [0.7]c 3 [0.9]c 5 [2.10]c 6 [2.11]c 11 [4.20]c

aResidual-lumen is computed for valves with all fused commissures.

bMean ± SD.