Published in final edited form as: Acad Radiol. 2013 Apr 17;20(7):847–853. doi: 10.1016/j.acra.2013.02.007

TABLE 2.

Overview of Sensitivities and Specificities in A Posteriori Simulated Double Reading Approaches (by Pairs of Radiologists) for XRM + ABUS (median [95% CI]) and the Changes with Respect to Single Reading Conditions

XRM + ABUS Double Reading Change wrt XRM + ABUS Single Reading Change wrt XRM Single Reading
Aggressive
 Sensitivity 71.0% [61.3%; 77.4%] 13.8% [11.2%; 17.3%] 44.4% [35.2%; 56.3%]
 Specificity 79.0% [64.7%; 90.2%] −11.6% [−12.8%; − 10.5%] −16.7% [−18.2%; −13.3%]
Conservative
 Sensitivity 48.4% [29.0%; 54.8%] −13.9% [−17.2%; − 11.1%] 16.7% [9.1%; 26.1%]
 Specificity 97.0% [95.4%; 99.3%] 11.6% [10.6%; 12.8%] 7.6% [6.0%; 9.2%]

ABUS, three-dimensional automated breast ultrasound; XRM, x-ray mammography.