Table 4.
Mean ± standard deviation values of confocal scanning laser ophthalmoscopy parameters with areas under the receiver operating characteristic curves and sensitivities at fixed specificities for discriminating between preperimetric glaucoma and control groups
Parameter | Glaucoma (n=48) | Control (n=86) | P Value* | AUC (SE) | Sensitivity (Specificity = 80%) | Sensitivity(Specificity = 95%) |
---|---|---|---|---|---|---|
Rim area (mm2) | 1.20 ± 0.05 | 1.38 ± 0.03 | < 0.001 | 0.72 (0.05) | 41.8% | 10.4% |
Rim volume (mm3) | 0.30 ± 0.02 | 0.38 ± 0.01 | 0.002 | 0.71 (0.05) | 52.3% | 11.6% |
Linear cup-to-disk ratio | 0.59 ± 0.02 | 0.52 ± 0.01 | 0.002 | 0.66 (0.05) | 41.6% | 25.0% |
Cup-to-disk area ratio | 0.36 ± 0.02 | 0.28 ± 0.01 | 0.003 | 0.66 (0.05) | 41.6% | 22.9% |
Rim-to-disk area ratio | 0.63 ± 0.02 | 0.71 ± 0.01 | 0.003 | 0.66 (0.05) | 29.0% | 6.9% |
RNFL CSA (mm2) | 1.07 ± 0.07 | 1.29 ± 0.05 | 0.005 | 0.65 (0.05) | 38.3% | 17.4% |
Global GPS | 0.54 ± 0.05 | 0.38 ± 0.03 | 0.006 | 0.64 (0.05) | 45.8% | 16.6% |
Mean RNFL thickness (mm) | 0.22 ± 0.01 | 0.26 ± 0.01 | 0.004 | 0.64 (0.05) | 36.0% | 9.3% |
Cup area (mm2) | 0.78 ± 0.08 | 0.59 ± 0.04 | 0.023 | 0.62 (0.06) | 37.5% | 18.7% |
Cup volume (mm3) | 0.24 ± 0.04 | 0.14 ± 0.01 | 0.016 | 0.62 (0.05) | 35.4% | 16.6% |
Mean cup depth (mm) | 0.28 ± 0.02 | 0.25 ± 0.01 | 0.071 | 0.58 (0.06) | 33.3% | 10.4% |
RNFL = retinal nerve fiber layer
AUC = area under the receiver operating characteristic curve
SE = standard error
RNFL CSA = retinal nerve fiber layer cross sectional area
Global GPS = global glaucoma probability score
For comparison of mean values of confocal scanning laser ophthalmoscopy parameters between glaucomatous and control eyes