Table 1. Raw and corrected (QuRE, ShoRAH) estimated error rates for the Roche's GS FLX Titanium XLR70, as estimated by shotgun-sequencing the plasmid TOPO2.1 with HCV/HIV-1 inserts, and mapping the reads against the TOPO2.1 reference using the QuRe read aligner/filter module.
error prevalence (standard error) by type | ||||||||
---|---|---|---|---|---|---|---|---|
data set (n = 70,000) | mapped (n;%) | error correction method | overall error prevalence (standard error) | insertions | deletions | mismatches | homopolymeric | non-homopolymeric |
HCV | 49,866; 71.24% | non-corrected | 1.26% (0.0096) | 0.40% (0.0054) | 0.39% (0.0054) | 0.47% (0.0059) | 1.33% (0.0168) | 1.22% (0.0117) |
QuRe | 0.19% (0.0037) | 0.02% (0.0012) | 0.14% (0.0032) | 0.02% (0.0014) | 0.27% (0.0076) | 0.14% (0.0040) | ||
ShoRAH | 0.18% (0.0037) | 0.00% (0.0000) | 0.12% (0.0031) | 0.06% (0.0021) | 0.24% (0.0073) | 0.14% (0.0041) | ||
HIV-1 | 62,303; 89.00% | non-corrected | 1.30% (0.0060) | 0.36% (0.0032) | 0.47% (0.0037) | 0.47% (0.0036) | 2.14% (0.0162) | 1.05% (0.0062) |
QuRe | 0.39% (0.0033) | 0.06% (0.0013) | 0.25% (0.0027) | 0.08% (0.0015) | 0.95% (0.0108) | 0.23% (0.0029) | ||
ShoRAH | 0.21% (0.0025) | 0.00% (0.0001) | 0.13% (0.0020) | 0.07% (0.0015) | 0.47% (0.0079) | 0.13% (0.0022) |