Table 3.
Agent | Procedure | ||
---|---|---|---|
Control | Ar gas | Ar plasma | |
NaCl control | 7.17 ± 0.48 N = 21 |
6.59 ± 0.48** N = 15 |
5.82 ± 0.52∗∗,#
N = 8 |
H2O2 | 6.17 ± 0.80* N = 14 |
5.62 ± 0.86* N = 15 |
4.59 ± 0.77∗,∗∗,#
N = 11 |
EDTA | 5.92 ± 0.37* N = 8 |
6.25 ± 0.43** N = 14 |
4.51 ± 0.82∗,∗∗,#
N = 16 |
Data are presented as mean lg (CFU/mL + 1) ± SD.
Ar: argon; CHX: 0.1% chlorhexidine; OCT: 0.1% octenidine; PHMB: 0.1% polyhexanide; NaOCl: 0.6% sodium hypochlorite; H2O2: 1.5% hydrogen peroxide; EDTA: 20% ethylenediaminetetraacetic acid.
*P < 0.05 versus NaCl control (within columns); **P < 0.05 versus control procedure (within rows); # P < 0.05 comparing Ar plasma versus Ar gas (within rows), two-sided Mann-Whitney U test, and reduction in saliva CFU/mL. P values were Bonferroni corrected.