Skip to main content
. 2013 Oct 4;8(10):e76414. doi: 10.1371/journal.pone.0076414

Table 1. Phenotypic characterization of the family members II-8, III-5, IV-7, IV-8, III-6 and III-9.

proband II-8 (affected) III-5 (affected) IV-7 (affected) IV-8 (affected) III-6 III-9
refraction at last examination OD -21.00-0.25/74°; OS -21.25sph OD -23.00sph; OS -22.75-0.5/43° OD -8.00-3.00/5°; OS -7.50-3.00/165° OD -2.75-2.25/160°; OS -3.0-1.5/174° OD/OS emmetropia OD +1.00-0.25/106°; OS +1.25-1.00/48°
age at last examination (y) 72 5151 8 3 45 43
best corrected visual acuity OD/OS (decimal scale) 0.01/0.014 0.16/0.2 0.2/0.2 0.125/0.125 1.0/1.0 1.0/0.8
nystagmus congenital congenital congenital no no no
orthoptic examination orthotropia orthotropia esotropia intermittent exotropia orthophoria esophoria
binocular vision none Bagolini Striated Glasses Test none Lang-Test localized, Titmus Fly Lang-Test Lang-Test
biomicroscopy Cataracta provecta Cataracta incipiens normal normal normal normal
fundoscopy myopic changes (including pigmentary abnormalities at the posterior pole) myopic changes (including pigmentary abnormalities at the posterior pole) discreet optic nerve atrophia, irregular pigmentation in the macular area discreet optic nerve atrophia, irregular pigmentation in the macular area normal normal
SD-OCT with artifacts (staphyloma, nystagmus) with artifacts (staphyloma, nystagmus) thin choroid, otherwise normal; fovea normal OS: fovea normal, OD: not reliable (cooperation) normal normal
visual fields Goldmann III 4e normal Goldmann III 4e normal Goldmann III 4e normal; 30.2 reduced sensitivity not examined 30.2 normal 30.2 normal
color vision severe red-green defects moderate red-green defects mild red-green defects not examined normal normal
dark adaptation not examined not examined elevated rod and cone thresholds (2 log units) not examined not examined not examined
scotopic ERG severely reduced, almost extinguished a- and b- wave severely reduced, almost extinguished a- and b-wave slightly reduced a- and b-wave, no “negative” ERG screening ERG below noise level low, but within normal ranges low, but within normal ranges
photopic ERG not recordable not recordable below noise level screening ERG below noise level normal normal
oscillatory potentials not recordable not recordable reduced not examined normal normal
30 Hz flicker ERG not recordable not recordable not recordable not examined normal with artefacts

OD = right eye, OS = left eye; SD-OCT = Spectral domain optic coherence tomography; ERG = electroretinogram