Skip to main content
. 2013 Sep 20;69(Pt 10):1889–1900. doi: 10.1107/S090744491301576X

Table 2. Metal-ion concentrations detected by ICP-AES.

  Ion concentration (mg l−1)
Sample Mg2+ Ca2+ Ni2+ Co2+ Zn2+
Tse3 alone 0.050 0.34 <0.002 <0.002 0.003
Tse3–Tsi3 0.046 0.42 <0.002 <0.002 0.018