Figure 5. Simulation results of the RESET switching with fixed Ea and R⊥.
(a) 10% G–V curves randomly selected from 1250 RESET cycles. The inset shows three typical G–V curves similar to those in Figure 1. (b)
and (c)
scatter plots for RESET1 (red circles) and RESET2 (blue circles). (d) Evolution of the conductance distribution with V in the 1250 successive RESET cycles. In this simulation, Ea = 1 eV, R⊥ = 5 × 106 K W−1.