Table 2.

Bone Biomarkers used in Clinical Practice

Biomarker Sample collection and Assay Predictor of
histomorphometry
Predictor of Fractures
PTH
  • Multiple assays and poor standardization between the various assays.

  • High diurnal variation.

  • Levels vary with temperature of plasma specimen.

  • PTH assays detects variable amounts of circulating C terminal fragments. Some fragments are potentially biologically active.

  • Co-efficient of variation within subject in hemodialysis patientsis 25.6%(64)

  • PTH levels higher with increased bone turnover than those with adynamic bone disease in CKD 3–5 (65)as well as CKD 5D(66).* No consistent relationship between PTH and bone formation rates or bone volume(67)

  • Racial differences(68)

  • Inconsistent results for risk stratification between high or low PTH and fractures(6971)

  • Decreased fracture risk after parathyroidectomy(7 2)

Bone Specific
Alkaline
Phosphatase
b-alp)
  • Co-efficient of variation within subject in hemodialysis patients is 12.5%(73)

  • Assay not widely available clinically

  • Cross reactivity of assay with the liver-derived alkaline phosphate fraction

  • b-alp levels are higher with higher bone turnover in CKD 5D(23, 74)*

  • No relationship of b-alp with bone volume (23, 75)

  • No prospective data on b-alp and risk of fractures in CKD

  • Higher risk of fractures in CKD 5D with high total alkaline phosphatase levels (76).

*

PTH measured by the intact assay (Elecsys PTH 91–84) assay, Roche Diagnostics corporation, Indianapolis, IN, USA) was equally predictive to bone-specific alkaline phosphatase (BAP) of underlying bone turnover with a sensitivity of 0.58 vs 0.403, a positive predictive value of 0.373 vs 0.287, and a negative predictive value of 0.903 vs 0.877 (PTH vs BAP, respectively) for the detection of increased bone formation rates. The two together did not improve sensitivity or specificity (46).