Table 2. Material type effects on MN axial (n = 5) and transverse (n = 2) failures.
Test Type | MN Type | Force/Needle (N) |
Axial Failure | PLGA (50∶50) | 1.06±0.02 |
SA (10% w/w) | 0.18±0.05 | |
Transverse Failure | PLGA (50∶50) | 0.46±0.04 |
SA (10% w/w) | 0.04±0.02 |
Both data are represented as the mean and SD.