Skip to main content
. 2013 Oct 24;9(10):e1003265. doi: 10.1371/journal.pcbi.1003265

Table 1. Causality results by Granger causality with signal-dependent noise analysis.

Intensity
OFC AntINS AntLPFC PostLPFC
OFC 4.51 (0.10) 0.96 (0.62) 0.68 (0.71)
AntINS 2.15 (0.34) 28.57 ( Inline graphic ) 13.59 (Inline graphic)
AntLPFC 0.89 (0.64) 28.44 ( Inline graphic ) 5.17 (0.08)
PostLPFC 0.62 (0.73) 29.62 ( Inline graphic ) 4.22 (0.12)

The causal influence is from row to column. The causality is given for each direction, and the corresponding Inline graphic-value is presented in brackets. If the uncorrected Inline graphic-value is less than Inline graphic (surviving Bonferroni correction), the causal influence is identified as significant and indicated in bold in the table. (*: The active-set algorithm was used.)