Skip to main content
. 2013 Oct 7;8(4):160–165.

Table 1. Frequency of procedural errors in canals detected using periapical radiographs and CBCT (Kolmogorov-Smirnov test).

Method n Fracture Canal Transportation Perforation P-value
Periapical radiograph 180 7 (3.88%) 4 (2.23%) 0 (0.00%) P>0.05
CBCT a 180 7 (3.88%) 3 (1.67%) 1 (0.56%) P>0.05

a. Cone beam computed tomography