Skip to main content
. Author manuscript; available in PMC: 2014 Apr 1.
Published in final edited form as: J Magn Reson. 2013 Feb 8;229:10.1016/j.jmr.2013.02.003. doi: 10.1016/j.jmr.2013.02.003

Table 3.

Data acquisition parameters used for 3T studies that applied automatic prescription of saturation bands

Author Plane
slice (mm)
Encoding
matrix
TR/TE
(ms)
Selection # sat
bands
Acquisition
time (s)
Ozkinsky et al,
2011 (41)
Axial
60mm
Flyback
EPSI (SI)
18×18×16
1500/144 PRESS
OP=
1.2
9 auto +
5×2 around
PRESS
box
6.5min
Ozhinsky et al,
2012 (43)
Automatic
oblique
60mm
Flyback
EPSI (SI)
18×18×16
1100/144 PRESS
OP =
1.5 or 1.2
9 auto +
5×2 around
PRESS
box
12min (lac- edited)
6min
otherwise
Martinez-Ramon et
al (2010)
(45)
Manual
oblique
45mm
PEPSI
(RL)
32×32×8
2000/11 Spin echo 16 auto 4.5 min
Yung et al (2011)
(46)
Manual
oblique
52mm
PEPSI
(RL)
32×32×8
2000/15 Spin echo 16 auto
from atlas
4.4 min