Comparison of different alkane bioreporters.

Host Regulation system Reporter Response time Detection limit Alkane detection range Reference
E. coli DH5α alkB‐alkS gfp 2.5 h 0.011 mg l−1a C6–C10 Jaspers et al. (2001)
E. coli DH5α alkB‐alkS luxAB 1.0−2.0 h 0.011 mg l−1a C6–C10 Sticher et al. (1997), Tecon et al. (2010)
E. coli DH5α alkBFGHJT luxAB 0.78 mg l−1 C6–C10 Minak‐Bernero et al. (2004)
Y. lipolytica OD600 24 h 0.85 mg l−1 C9–C12 Alkasrawi et al. (1999)
A. baylyi ADP1 alkM‐alkR lacZ 10 h C7–C18 Ratajczak et al. (1998a)
A. baylyi ADP1 alkM‐alkR luxCDABE 0.5 h 0.1 mg l−1b C7–C36 Zhang et al. (2011) and this study
a.

The detection limit for octane only.

b.

The detection limit for octadecane is 8.6 × 10−4 mg l−1.