Table 1. Relative response factor (R/R0)a, linearity of measurement, correlation coefficient (r2), limits of quantitation (LOQs)b, extraction yield, and method accuracyc analyses.
Analytes | Extraction Yield (%) |
Accuracy (% ± SD) |
R/R0 | LoQ (pg) | Calibrated range (pg) |
Correlation coefficient (r2 ) |
Internal standard |
---|---|---|---|---|---|---|---|
9-HODE | 98 | 95.0 ± 8.5 | 1.10 ± 0.11 | 0.05 | 0.05–300 | 0.9977 | 13-HODE-d4 |
13-HODE | 90 | 105.0 ± 12.5 | 1.08 ± 0.08 | 0.07 | 0.07–300 | 0.9956 | 13-HODE-d4 |
9-OxoODE | 84 | 86.2 ± 5.0 | 0.72 ± 0.05 | 0.5 | 0.5-1000 | 0.9990 | 13-HODE-d4 |
13-OxoODE | 88 | 97.8.0 ± 7.3 | 0.88 ± 0.12 | 1.0 | 1.0–1000 | 0.9987 | 13-HODE-d4 |
9,10-DiHOME | 80 | 103.0 ± 15.0 | 1.05 ± 0.15 | 0.08 | 0.08-300 | 0.9991 | 9,10-DiHOME-d4 |
12,13-DiHOME | 77 | 94.2.0 ± 3.4 | 0.99 ± 0.10 | 0.04 | 0.04-300 | 0.9989 | 12,13-DiHOME-d4 |
9(10)-EpOME | 76 | 91.5 ± 9.5 | 0.78 ± 0.10 | 0.5 | 0.5-1000 | 0.9999 | 9,10-DiHOME-d4 |
12(13)-EpOME | 80 | 95.0 ± 8.5 | 0.75 ± 0.11 | 0.5 | 0.5-1000 | 0.9945 | 9,10-DiHOME-d4 |
Resolvin D1 | 75 | 94.1 ± 10.4 | 0.40 ± 0.10 | 5.0 | 5.0-1000 | 0.9998 | PGE2-d4 |
Resolvin D2 | 79 | 110.0 ± 14.8 | 0.55 ± 0.12 | 6.0 | 6.0-1000 | 0.9937 | PGE2-d4 |
10,17- DiHDoHEA |
85 | 98.0 ± 10.3 | 0.40 ± 0.08 | 0.5 | 0.5-500 | 0.9960 | PGE2-d4 |
19,20-DiHDPA | 103 | 97.2 ± 7.8 | 5.80 ± 0.75 | 0.5 | 0.5-500 | 0.9948 | PGE2-d4 |
17-HDoHE | 82 | 95.2 ± 10.1 | 1.20 ± 0.20 | 2.0 | 2.0–1000 | 0.9950 | 12-HETE-d8 |
16-HDoHE | 78 | 99.0 ± 3.5 | 1.25 ± 0.16 | 2.0 | 2.0–1000 | 0.9984 | 12-HETE-d8 |
14-HDoHE | 78 | 93.8 ± 8.8 | 1.18 ± 0.10 | 1.0 | 1.0–1000 | 0.9989 | 12-HETE-d8 |
13-HDoHE | 83 | 105.0 ± 11.2 | 1.32 ± 0.20 | 2.0 | 2.0–1000 | 0.9995 | 12-HETE-d8 |
11-HDoHE | 77 | 101.0 ± 8.5 | 1.15 ± 0.22 | 2.0 | 2.0–1000 | 0.9966 | 12-HETE-d8 |
10-HDoHE | 81 | 88.0 ± 7.8 | 1.40 ± 0.08 | 2.0 | 2.0–1000 | 0.9984 | 12-HETE-d8 |
8-HDoHE | 82 | 90.2 ± 9.9 | 1.05 ± 0.15 | 1.0 | 1.0–1000 | 0.9919 | 12-HETE-d8 |
7-HDoHE | 79 | 102.0 ± 8.5 | 1.20 ± 0.11 | 1.0 | 1.0–1000 | 0.9963 | 12-HETE-d8 |
4-HDoHE | 83 | 108.0 ± 4.5 | 1.00 ± 0.08 | 1.0 | 1.0–1000 | 0.9994 | 12-HETE-d8 |
6keto-PGF1α | 85 | 106.3 ± 8.5 | 0.95 ± 0.05 | 0.1 | 0.1–5000 | 0.9984 | TXB2-d4 |
TXB2 | 88 | 100.2 ± 3.5 | 1.03 ± 0.03 | 0.1 | 0.1–500 | 0.9990 | TXB2-d4 |
PGF2α | 78 | 98.1 ± 7.1 | 0.91 ± 0.03 | 0.4 | 0.4–500 | 0.9988 | PGE2-d4 |
PGF1α | 80 | 108.2 ± 5.2 | 2.10 ± 0.03 | 0.1 | 0.1–500 | 0.9917 | PGE2-d4 |
PGE2 | 77 | 99.1 ± 4.2 | 1.02 ± 0.03 | 0.3 | 0.3–500 | 0.9981 | PGE2-d4 |
PGE1 | 73 | 103.1 ± 7.1 | 1.42 ± 0.11 | 0.2 | 0.2–500 | 0.9972 | PGE2-d4 |
PGD2 | 73 | 92.1 ± 10.2 | 0.66 ± 0.07 | 0.5 | 0.5–1000 | 0.9981 | PGE2-d4 |
LTB4 | 65 | 98.8 ± 9.1 | 1.02 ± 0.02 | 0.7 | 0.7–1000 | 0.9992 | LTB4-d4 |
20-HETE | 76 | 105.1 ± 3.1 | 2.20 ± 0.10 | 0.3 | 0.3–500 | 0.9977 | 12-HETE-d8 |
15-HETE | 68 | 97.2 ± 9.2 | 1.10 ± 0.18 | 0.6 | 0.6–1000 | 0.9953 | 12-HETE-d8 |
12-HETE | 66 | 99.9 ± 8.1 | 1.00 ± 0.05 | 0.7 | 0.7–1000 | 0.9969 | 12-HETE-d8 |
11-HETE | 73 | 97.9 ± 4.2 | 1.32 ± 0.13 | 0.5 | 0.5–1000 | 0.9973 | 12-HETE-d8 |
8-HETE | 80 | 103.1 ± 5.5 | 1.50 ± 0.12 | 0.5 | 0.5–1000 | 0.9972 | 12-HETE-d8 |
5-HETE | 70 | 108.4 ± 7.2 | 0.82 ± 0.08 | 0.8 | 0.8–1000 | 0.9999 | 12-HETE-d8 |
14,15-EET | 75 | 94.3.1 ± 4.4 | 0.91 ± 0.11 | 0.8 | 0.8–1000 | 0.9989 | 12-HETE-d8 |
11,12-EET | 80 | 98.9 ± 6.7 | 0.80 ± 0.08 | 0.8 | 0.8–1000 | 0.9982 | 12-HETE-d8 |
8,9-EET | 79 | 101.0 ± 9.9 | 0.75 ± 0.14 | 0.8 | 0.8–1000 | 0.9991 | 12-HETE-d8 |
5,6-EET | 85 | 106.2 ± 7.7 | 0.95 ± 0.08 | 0.5 | 0.5–1000 | 0.9990 | 12-HETE-d8 |
Relative response factor (R/R0) was calculated as the ratio of an equivalent amount of analyte (R) to its internal standard (R0) and expressed as the mean ± standard deviation (N=3).
LOQ was defined as 3 × the limit of detection which is expressed as pg injected on column resulting an signal to noise ratio of 3:1.
Method accuracies were calculated as the percent deviation from the expected concentrations and expressed as the mean ± standard deviation (n= 3 experiments).