Skip to main content
. Author manuscript; available in PMC: 2014 Dec 1.
Published in final edited form as: Otol Neurotol. 2013 Dec;34(9):10.1097/MAO.0b013e3182979398. doi: 10.1097/MAO.0b013e3182979398

Table 1.

Patients implanted due to profound hearing loss caused by otosclerosis.

Case Gender Age (yrs) CI usage time (yrs) Implanted ear Device Configuration/Strategy Electrode shape FNS Electrodes causing FNS
1 M 84 10 AS Ineraid® MP/CIS Straight No -
2 M 77 11 AD Ineraid® MP/CIS Straight No -
3 F 69 4 AS Nucleus® 24M MP/ACE Straight Yes 15–17
4 F 73 4 AS Nucleus® 24M MP/ACE Straight No -
5 F 73 17 AD Nucleus® 22 BP/SPEAK Straight No -
6 M 80 19 AD Nucleus® 22 BP/SPEAK Straight Yes 12,16
7 F 74 8 AS HF® II w/p MP/HiRes Perimodiolar No -
8 F 74 8 AD HF® II w/p MP/HiRes Perimodiolar No -
9 M 83 23 AS Nucleus® 22 BP/SPEAK Straight Yes 15–17
10 M 76 8 AS Nucleus® 24R MP/ACE Perimodiolar No -
11 M 89 17 AS Nucleus® 22 BP/SPEAK Straight Yes 14–18
12 M 87 3 AD Nucleus® 22 BP/SPEAK Straight No -
13 M 74 2 AS Nucleus® 22 BP/SPEAK Straight No -

M: Male; F: Female; AD: Right; AS: Left; HF® II w/p: Hi Focus II with positioner; BP: Bipolar; MP: Monopolar.