Skip to main content
. 2013 Sep 5;42(9):20120459. doi: 10.1259/dmfr.20120459

Table 3.

The mean areas under receiver operating characteristic curves [Az (SD)] of three observers for diagnosis of vertical root fractures

Group Dolphin InVivo KDIS3D Xoran
UN 0.83 (0.04) 0.77 (0.04) 0.83 (0.04) 0.80 (0.03)
GP 0.80 (0.03) 0.85 (0.03) 0.76 (0.04) 0.80 (0.04)
Post 0.72 (0.04) 0.75 (0.05) 0.71 (0.05) 0.77 (0.06)
Overall 0.79 (0.02) 0.79 (0.02) 0.79 (0.02) 0.78 (0.02)

GP, gutta-percha; Post, intracanal post; SD, standard deviation; UR, unrestored.

Means that are italicised are statistically different (p < 0.05).

Dolphin (Dolphin Imaging & Management Solutions, v. 11.5) is manufactured by Patterson Dental Supply, Inc., St Paul, MN; InVivo (InVivoDental, v. 5.0) by Anatomage Inc., San Jose, CA; KDIS3D (Kodak Dental Imaging Software 3D module, v. 2.1.11) by Carestream Health Inc., Rochester, NY; and Xoran (Xoran CAT™, v. 3.0.34) by Xoran Technologies, Ann Arbor, MI.