Skip to main content
. 2013 Nov 14;14:321. doi: 10.1186/1471-2474-14-321

Table 2.

Angle measurements in CON and CAOS and inter- and intraclass correlation coefficients

Angle CON CAOS P-value Inter-class correlation coefficient Intra-class correlation coefficient
Chi (min-max)(SD)
180.3 (174–186)(2.83)
180.7 (175–187)(2.38)
0.23
0.90
0.83
Alpha (min-max)(SD)
89.4 (84–95)(2.38)
90.3 (87–95)(1.52)
<0.01
0.92
0.89
Beta (min-max)(SD)
90.7 (87–94)(1.61)
90.0 (87–95)(1.66)
<0.01
0.95
0.91
Gamma (min-max)(SD)
4.39 (0–11)(2.39)
7.22 (0–16)(3.51)
 
0.95
0.81
Sigma (min-max)(SD) 89.9 (84–95)(2.26) 86.2 (79–95)(2.96)   0.98 0.95

For gamma and sigma, target value was different for CON and CAOS; consequently p-value is not shown.

ICC is >0.80 for all angle measurements, which is considered a good reliability.