Table 3.
Mean subjects | Power | Early success | Early futility | % Randomized to best arm | Mean trial duration (months) | |
---|---|---|---|---|---|---|
Design 1: early stopping only | ||||||
Null | 39487 | 0.03 | 0.023 | 0.875 | 1.00 | 60 |
Alternative | 39513 | 0.93 | 0.895 | 0.005 | 0.63 | 56 |
One Works | 39637 | 0.70 | 0.657 | 0.112 | 0.21 | 66 |
Better & Best | 39649 | 0.73 | 0.669 | 0.082 | 0.21 | 66 |
Worse | 35286 | 0.00 | 0.000 | 1.000 | 0.37 | 29 |
Design 2: probability-weighted adaptive randomization; no arm dropping | ||||||
Null | 39504 | 0.02 | 0.020 | 0.905 | 1.00 | 59 |
Alternative | 39400 | 0.93 | 0.900 | 0.016 | 0.66 | 56 |
One Works | 39537 | 0.75 | 0.708 | 0.091 | 0.32 | 63 |
Better & Best | 39634 | 0.75 | 0.707 | 0.091 | 0.30 | 64 |
Worse | 34755.3 | 0.00 | 0.000 | 1.000 | 0.34 | 28 |
Design 3: information-weighted adaptive randomization; no arm dropping | ||||||
Null | 39624 | 0.02 | 0.018 | 0.896 | 1.00 | 60 |
Alternative | 39443 | 0.93 | 0.901 | 0.012 | 0.66 | 56 |
One Works | 39595 | 0.75 | 0.708 | 0.093 | 0.28 | 66 |
Better & Best | 39711 | 0.78 | 0.742 | 0.075 | 0.27 | 65 |
Worse | 35118 | 0.00 | 0.000 | 1.000 | 0.34 | 29 |
Design 4: probability-weighted adaptive randomization; 5% arm dropping | ||||||
Null | 39557 | 0.02 | 0.018 | 0.897 | 1.00 | 60 |
Alternative | 39395 | 0.91 | 0.889 | 0.01 | 0.66 | 57 |
One Works | 39658 | 0.79 | 0.728 | 0.094 | 0.34 | 64 |
Better & Best | 39641 | 0.76 | 0.707 | 0.09 | 0.30 | 65 |
Worse | 34683 | 0.00 | 0 | 1 | 0.34 | 28 |
Design 5: information-weighted adaptive randomization; 10% arm dropping | ||||||
Null | 39377 | 0.03 | 0.022 | 0.905 | 1.00 | 59 |
Alternative | 39503 | 0.92 | 0.885 | 0.013 | 0.66 | 56 |
One Works | 39622 | 0.74 | 0.704 | 0.088 | 0.29 | 66 |
Better & Best | 39726 | 0.74 | 0.7 | 0.07 | 0.27 | 66 |
Worse | 35142 | 0.00 | 0 | 1 | 0.34 | 29 |
Design 6: no adaptive randomization; arm dropping 20% vs control | ||||||
Null | 38568 | 0.02 | 0.022 | 0.736 | 1.00 | 56 |
Alternative | 39369 | 0.92 | 0.901 | 0.012 | 0.79 | 55 |
One Works | 39256 | 0.69 | 0.645 | 0.104 | 0.20 | 63 |
Better & Best | 39404 | 0.71 | 0.656 | 0.103 | 0.22 | 64 |
Worse | 31700 | 0.00 | 0.000 | 0.190 | 0.00 | 26 |
Design 7: no adaptive randomization; predictive probability-based arm dropping | ||||||
Null | 38630 | 0.022 | 0.020 | 0.88 | 1.00 | 57 |
Alternative | 34337 | 0.91 | 0.87 | 0.012 | 0.67 | 57 |
One Works | 37303 | 0.69 | 0.64 | 0.11 | 0.25 | 67 |
Better & Best | 37032 | 0.70 | 0.65 | 0.08 | 0.24 | 68 |
Worse | 34323 | 0.00 | 0.00 | >0.99 | 1.00 | 27 |