Skip to main content
. 2013 Aug 27;170(2):380–390. doi: 10.1111/bph.12289

Table 1.

Average coronary flow and end-diastolic pressures at the end of perfusion in the isolated perfused rat hearts

Type of perfusion
Aerobic I/R (20/30)
Compound ML-7 Y-27632 Doxy
Concentration (μM) 1 5 0.05 1 1 30
n 9 9 7 9 7 6 9 9
Coronary flow (mL·min−1) 17.30 6.267* 4.029* 15.44# 6.671* 14.83# 6.111* 15.18#
SEM ± 0.5548 ± 1.452 ± 1.587 ± 0.8577 ± 2.149 ± 0.5578 ± 1.404 ± 1.033
End-diastolic pressure (mmHg) 12.11 41.67* 28.44* 11.00# 28.78 21.44*,# 33.33* 22.33*,#
SEM ± 0.5386 ± 6.205 ± 4.451 ± 0.7638 ± 5.449 ± 1.634 ± 3.329 ± 2.421
Compound Y-27632 + ML-7 Y-27632 + Doxy ML-7 + Doxy Y-27632 + ML-7 + Doxy
Concentration (μM) 0.05 + 1 0.05 + 1 1 + 1 0.05 + 1 + 1
N 9 9 9 9
Coronary flow (mL·min−1) 9.667* 10.67* 10.99* 15.69#
SEM ± 1.936 ± 1.785 ± 1.787 ± 0.3638
End-diastolic pressure (mmHg) 18.89*,# 35.33* 31.11* 15.89#
SEM ± 1.720 ± 6.526 ± 4.931 ± 2.150
*

P < 0.05 versus aerobic;

#

P < 0.05 versus I/R.