Table 4. Studies comparing the use of miniplates with no plates in cervical laminoplasty: postoperative complication rates.

Wang et al9 Jiang et al10
Plates, % No plates, % Plates, % No plates, %
Reoperation
Reoperation (causes) 0 (0/25) 13 (3/24)
Cause: restenosis (n = 3)
NR NR
Pain
Axial pain NR NR 38 (12/32) 35 (6/17)
Shoulder pain (bilateral) 4 (1/25) 8 (2/24) NR NR
Neurological complications
Restenosis 0 (0/25) 13 (3/24) 0 (0/32) 0 (0/17)
C5 radiculopathy/C5 palsy (transient) 4 (1/25) 13 (3/24) 3 (1/32) 6 (1/17)
C7 radiculopathy NR 4 (1/24) NR NR
Numbness (right shoulder) 4 (1/25) NR NR NR
Infection
Wound (superficial) 0 (0/25) NR 6 (2/32) 12 (2/17)
Surgical complications
CSF leakage 4 (1/25) 4 (1/24) NR NR
Spinal cord injury 0 (0/25) 0 (0/24) NR NR
Bleeding 0 (0/25) 0 (0/24) NR NR
Other complications
Cardiopulmonary event NR NR NR 6 (1/17)
Failed plates 0 (0/25) n/a 0 (0/32) n/a

Abbreviations: CSF, cerebrospinal fluid; n/a, not applicable; NR, not reported.