Skip to main content
. 2012 Dec;1(6):255–258. doi: 10.1089/wound.2011.0283

Figure 2.

Figure 2.

Results from a controlled laboratory study demonstrating slippage. Ten different compression systems (Coban 2 Lite system, Coban 2 Layer Compression System [3M]; Rosidal sys, Dauerbinde F, and Rosidal K [all from Lohmann & Rauscher]; ProGuide™, Profore Lite, and Profore [all from Smith & Nephew]; KTwo [Laboratoires Urgo]; and Actico [Activa Healthcare Ltd.]) were applied by 10 different bandaging experts to a total of 120 legs (60 healthy volunteers, both legs wrapped) and worn for 48 h. Average slippage values were calculated for each bandage at 24 and 48 h.