Abstract
Physisorption on solid surfaces is important in both fundamental studies and technology. Adsorbates can also be critical for the performance of miniature electromechanical resonators and sensors. Advances in resonant nanoelectromechanical systems (NEMS), particularly mass sensitivity attaining the single-molecule level, make it possible to probe surface physics in a new regime, where a small number of adatoms cause a detectable frequency shift in a high quality factor (Q) NEMS resonator, and adsorbate fluctuations result in resonance frequency noise. Here we report measurements and analysis of the kinetics and fluctuations of physisorbed xenon (Xe) atoms on a high-Q NEMS resonator vibrating at 190.5 MHz. The measured adsorption spectrum and frequency noise, combined with analytic modeling of surface diffusion and adsorption–desorption processes, suggest that diffusion dominates the observed excess noise. This study also reveals new power laws of frequency noise induced by diffusion, which could be important in other low-dimensional nanoscale systems.
Keywords: Nanoelectromechanical systems (NEMS), surface adsorbate, adsorption–desorption, diffusion, resonator, noise
Physisorption of atomic or molecular species is ubiquitous in virtually all circumstances where solid–gas interfaces exist (e.g., catalysis, adhesion). In physics, directly observing and manipulating individual adsorbed atoms on ultraclean surfaces represents a significant experimental feat.1 Engineering of atomic and molecular structures on certain surfaces also plays important roles in emerging applications including programmable self-assembly,2,3 nanoscale lithography,4 and nanotribology.5 For solid-state transducers, especially high-precision detectors and sensors, surface adsorbate can have important influences on device performance.6 Electromechanical resonators with high quality factor (Q), particularly quartz crystal microbalances (QCMs), are widely used to measure the mass, and other physical and electrochemical properties of the adsorbed layers, by monitoring changes of the QCM resonance frequency, Q factor, or amplitude.7,8 Resonant nanoelectromechanical systems (NEMS) sensors have recently demonstrated significantly enhanced mass sensitivities, down to the level of several, or even single, noble gas atoms,9–11 representing an improvement up to 1012-fold over a conventional QCM. Such sensitivity levels provide the new opportunity of employing NEMS to directly probe the effects of surface adsorbate, on very small surface areas (typically of the order of only ~100 nm × 1 µm) and in the submonolayer regime. This approach can effectively complement and advance today’s prevailing experimental techniques in surface science (e.g., spectroscopy and ellipsometry for surface thermodynamics, atomic force microscopy, scanning tunneling microscopy, quasielastic atom scattering for surface diffusion, and QCM for interfacial friction).12 As an initial step toward this new paradigm, in this work we employ a high-Q, very high frequency (VHF) NEMS resonator to investigate the behavior of physisorbed xenon (Xe) atoms, by performing precise measurements of the excess frequency noise that arises from statistical fluctuations of the adsorbed atoms on the resonator surface.
The core of our experimental apparatus (Figure 1a) consists of a NEMS resonator and a micro gas nozzle, well aligned and in close proximity. The NEMS resonator is a doubly clamped beam with dimensions 2.3 µm (L) × 150 nm (w) × 100 nm (t). It is surface-nanomachined from a 100 nm silicon carbide (SiC) layer on silicon (Si) substrate, in a process detailed elsewhere.13 Metallization and passivation of the device consist of a 30 nm film of thermally evaporated aluminum (Al) capped with 5 nm titanium (Ti). At least part of the top Ti film upon exposure to air turns into native oxide (TiO2),14 which is not only an excellent passivation layer but also a popular surface for biochemical species and a remarkable catalyst.15,16
The device is electrically connected onto a dedicated chip carrier (with an embedded circuit board) and mechanically and thermally anchored to a massive sample stage (brass, gold plated). The sample stage is loaded into an ultrahigh-vacuum (UHV) cryostat, first pumped down at room temperature overnight (to ~5 × 10−7 Torr) and then cooled down in liquid helium (LHe). The device temperature is precisely measured and regulated by a calibrated on-board thermometer and a closed-loop temperature controller. We employ the magnetomotive scheme9,13 to excite the device into resonance and detect its response. The orientation of the magnetic field is such that the out-of-plane flexural modes are excited; the calculated modal mass of the resonator is Meff ≈ 96 fg. Figure 1c displays the measured response at a temperature T ≈ 58 K, showing the sharp (Q ≈ 5620) fundamental-mode flexural resonance at a frequency f0 ≈ 190.5 MHz, corresponding to an effective stiffness keff ≈ 145 N/m. We have incorporated the NEMS resonance signal readout (Figure 1b) into a low-noise, frequency-modulation phase-locked loop (FM PLL) circuitry.9,17 This enables frequency locking and tracking of the resonance, hence real-time monitoring of the frequency variations that reflect the thermodynamic effects of adsorbates on the device surface. Prior to investigating the real-time behavior of surface adsorbates, we perform extensive tests and careful calibrations of the device response to a steadily increasing mass-load using the FM PLL technique. Figure 1d shows the calibration of the excellent mass responsivity of the device, ℛ ≡ |∂f0/∂M| = 0.99 Hz/zg [i.e., a resonance frequency shift of ~1 Hz per zg (10−21 g) of loaded mass].
Adsorbates are delivered to the NEMS resonator via a micro gas nozzle (Figure 1a) fed by a gas delivery system connected to a buffer chamber. The nozzle has a circular aperture of 300 µm in diameter. It operates at low gas density as an effusive cell18 to produce an atomic beam of Xe impinging onto the NEMS surface. The cell’s gas kinetics determines the Xe atoms impinging rate I (atoms per unit area per unit time), which can be converted into an effective pressure of the impinging gas phase above the device, via p = I(2πmXekBT)1/2, where kB is the Boltzmann constant and T is the device temperature. In this study, the calibrated constant flux delivered by the nozzle is I = 2.7 × 1017 atoms/(m2·s). This corresponds to a local effective pressure of p = 6.8 × 10−8 Torr at a device temperature T = 60K. The cross section area of the device exposed to the well-aligned incoming atomic beam is AD = Lw = 3.45 × 10−13 m2. A flat surface with this area can accommodate an ideal close-packed monolayer of Na,est ≈ 2.2 × 106 Xe atoms (with a Lennard-Jones diameter dXe ≈ 0.41 nm); Na,est is thus the estimated number of available adsorption sites in the limit of an ideal, flat, and clean surface.
We choose to introduce Xe gas to the NEMS surface due to its relatively large atomic mass (mXe = 131.3 amu) and for its record as a classic prototype for studying physisorption in surface science.19 Existing Xe physisorption studies, however, are primarily limited to ideal, smooth, often specially treated metal surfaces,12,19 where a realistic description of the surface processes can be tackled in quantitative analyses or computer simulations.19 In ordinary and more practical situations involving nonideal, nonmetal, and disordered surfaces, understanding of adsorbates dynamics is particularly poor; quantitative studies and experimental approaches are greatly needed. On the surface of a resonating NEMS device, as sketched in Figure 1e, the behavior of Xe atoms is intriguing and may include both adsorption–desorption (out-of-plane) and surface diffusion (in-plane) processes. Because conventional sensors lack the necessary sensitivity, no experiment has been carried out to investigate the contribution of these processes to resonance frequency fluctuations. Note that the frequency variations depend not only on the total number of adsorbed Xe atoms, but also on their distribution and fluctuations on the device surface (e.g., along the length of the device, in this study).
We first measure the adsorption spectrum N(T), i.e., number of adsorbed Xe atoms as a function of the regulated device temperature T. As the device is cooled down, N(T) increases. We call this process temperature-programmed adsorption (TPA, see Supporting Information). Such variations are precisely measured as the resonance frequency change Δfm due to the mass-loading effect of the adsorbates, Δfm = N(T)ℛmXe. Figure 2 demonstrates the measured adsorption spectrum and effective surface overage in the temperature range T ≈ 58–80 K. For a given incoming atom flux, the TPA process is highly repeatable and reversible, by regulating the device temperature back and forth in the appropriate temperature range. Unlike conventional Langmuir isotherm adsorption spectra (i.e., surface coverage versus pressure of the gas phase, at constant surface temperature), the data here are closer to isobars (number of adsorbates versus device temperature, at constant pressure of the gas phase).20 We note that, in our measurements with the above value of the atom flux, when the device is cooled down to a temperature lower than T ≈ 56 K, the FM-PLL consistently experiences such a sudden and steep frequency shift that it cannot sustain the locking and tracking of the NEMS resonance; we call this phenomenon “PLL runaway”. We presume that the inflection point before the onset of this behavior represents an equivalent one-monolayer coverage, beyond which very fast accumulation of Xe atoms occur on the surface, leading to the so-called “wetting”-like behavior (i.e., abrupt formation of multilayer Xe films on device surface, which is dramatic and the associated frequency shift causes the PLL runaway).21 The measured frequency shift before PLL runaway is Δfmon ≈ 590 kHz and the corresponding number of atoms is Na,exp ≈ 2.7 × 106. This value strongly supports our identification of PLL runaway with the completion of a monolayer. The slightly higher value (~20%) compared to our prediction Na,est for an ideally flat surface is very reasonable considering the small but nonzero roughness of the device surface, and the uncertainty in determining the device geometry and actual surface area. After repeatedly experiencing the PLL runaway and identifying the temperature at which it occurs, we focus our experiments in the range T ≈ 58–80 K where the TPA is highly reversible and easily controllable.
The measured temperature-regulated surface coverage (Figure 2a), θ(T) = N(T)/Na,exp, helps to reveal the thermodynamics between the surface adsorbates and the gas phase. The adsorbing rate (atoms per unit area per second), ra = sI, is a fraction of the atoms impinging rate, with the ratio s being the sticking coefficient. We take s = 1 as customarily done for Xe impinging on very cold surfaces.22 We model the temperature dependence of the rate of atoms leaving the surface as a thermally activated process following the Arrhenius law, that is, by a surface-detaching rate rd = νa exp(−Ea/kBT), where Ea is the activation energy and va the attempt frequency. The steady-state balance between the gas phase and surface adsorbates dictates raAD = Nrd, hence N(T) = (sIAD/νa)exp(Ea/kBT). As shown in Figure 2b, this simple model neatly fits the experimental data, yielding Ea ≈ 63.1 meV (±0.23 meV), and va ≈ 1.23 × 104 Hz(±0.05 × 104 Hz). Note the va value from the fit is less reliable than the Ea value (va is more sensitive to fitting uncertainties, also depending on accurate determination of several experimental parameters). The extracted Ea is substantially smaller than the desorption energy reported for Xe on TiO2 surfaces,23,24 in the range of Edes ~ 200–300 meV (note that reported desorption energy data for Xe on crystalline metals or graphite are also in this range22,25,26). We recall that atoms can leave the device surface via either desorption into vacuum or lateral diffusion (Figure 1d); both processes can be described by an Arrhenius equation, where however the activation energy of the diffusion process is generally much smaller. Indeed, we find the measured activation energy to be in good agreement with typical reported values of the lateral diffusion energy barrier Ediff of Xe on surfaces (e.g., Ediff ≈ 52.1 meV,25 54 meV,27 moderately higher than the Xe–Xe binding energy, ~20 meV). This suggests that in our experiment the dynamic balance of surface adsorbates could be primarily between the adsorbing atoms from the nozzle and the atoms diffusing off the NEMS resonator.
To gain more insight beyond the above steady-state picture provided by the TPA and the initial surface kinetics analysis, we further carefully probe the fluctuations of the surface adsorbates by investigating the noise behavior of the VHF NEMS resonator while tuning the surface coverage via the device temperature. We measure the frequency instability of the NEMS resonator, quantified by the Allan deviation,28 σA(τA)=[1/(2(N − 1)) , with f̄i being the average frequencies measured over an averaging time τA = 1 s by employing the FM-PLL technique. We first measure the baseline instability without the Xe flux (Allan deviation σA,sys); and then again with the Xe flux. Figure 3 shows the measured Allan deviation as a function of device temperature. The axis on the right shows the corresponding mass fluctuations (at zeptogram scale) set by the frequency instability. The instability measured without Xe flux represents the noise floor of the system and slightly decreases as temperature is lowered. This corresponds to the mild but steady increase of the Q factor that we observe upon cooling the device in this temperature range (see Supporting Information). With the introduction of surface adsorbates, excess instability arises, clearly noticeable in Figure 3 for T < 70 K. Also visible are a few small peaks distributed in the Allan deviation plot. The fact that these small peaks appear in the data with surface adsorbates but not in the noise floor data suggests the existence of some interesting surface processes. We hypothesize that they may be related to the details of certain collective behavior of the adsorbed atoms, which could be dependent on roughness and structural irregularity of the surface (e.g., terraces, defects).
To understand the trend displayed by the measured data in Figure 3, we have developed analytic models for the two processes, adsorption–desorption and surface diffusion, that we consider relevant. We first examine the frequency noise due to adsorption–desorption. The adsorption–desorption noise model (see Supporting Information) deals with nondiffusive (i.e., laterally immobile) adsorbates at submonolayer coverage, in a fashion similar to an earlier work modeling surface contaminants on a quartz crystal resonator.29 Figure 2a shows the measured effective surface coverage θ(T) and the surface occupation deviation σocc = [N(Na − N)]1/2/Na = [θ(1 − θ)]1/2 (note that the surface occupation variance is , where Na = Na,exp is the number of adsorption sites, and rad and rdes are pure adsorption and desorption rates per adsorption site (in Hz), respectively. Clearly σocc has a maximum at θ = 1/2. Assuming pure adsorption–desorption, a characteristic correlation time can be defined for this process as τr = 1/(rad+rdes) = N/(sIAD), which is computed using the measured data and is plotted in the inset of Figure 2b. This leads to the excess Allan deviation σA,ad–des(τA) ≈ 0.29σocc·(Na)1/2(m/M)(τA/τr)1/2 in our experimental regime (see Supporting Information). Therefore, considering only adsorption–desorption noise and system noise, the total expected instability is . As displayed in Figure 3 (dark gray lines, note that σA,sys ≫ σA,ad–des hence σA,ad,total ~ σA,sys, hardly distinguishable), the estimated adsorption–desorption noise contribution is much lower even than the system noise floor, thus cannot account for the measured frequency instability in the presence of a Xe flux.
This predicted low adsorption–desorption noise and the above kinetics data (Ea ~ Ediff ≪ Edes) suggest that desorption cannot be the dominant mechanism of Xe atoms leaving the device surface. Hence we have developed a model to analyze noise due to Xe atoms diffusion on the device surface (see details in Supporting Information). We compute the autocorrelation function G(τ) of the fractional frequency fluctuations y(t) ≡ δf(t)/f0 induced by Xe atoms diffusion
(1) |
with τD = L2/(2a2D) being the characteristic diffusion time, a = 4.42844 is a constant determined by the shape of the fundamental mode of the device, and M is the device’s total mass. The associated spectral density of fractional frequency fluctuation is
(2) |
with ξ(x) ≡ g(√x)/√x, and g(√x) = cos(x) + sin(x) − 2C1(√x)cos(x) − 2S1(√ x)sin(x), where C1(x) and S1(x) are the Fresnel integrals30 (see details in Supporting Information), and ω = 2πf is the Fourier (offset) frequency.
The measured noise spectra of fractional frequency fluctuations (Figure 4a) clearly demonstrate that there is excess noise due to surface Xe adsorbates. In the case of no e, the spectrum exhibits 1/f oise at very low offset frequency (~0.1–2 Hz) and flattens out above 2 Hz, indicating the instrumentation noise floor of the system. Figure 4b shows the adsorbate-induced excess noise spectrum, Sy,Xe(ω) = Sy,total(ω) − Sy,noXe(ω), extracted from such measurements performed at four different temperatures in the range of interest. We compute the diffusion time τD by numerically fitting the measured spectral density data to eq 2, as shown in Figure 4c. The measurement and analysis yield τD ~ 0.05–0.11s, and we obtain the corresponding diffusion coefficient D = L2/(2a2τD) to be in the range of D ~ 1.2–2.5 × 10−8cm2/s (we note this is at the same level as reported for Xe diffusion on some other surfaces25). In Figure 4a and b, on the right axis we also show the corresponding adsorbed Xe mass fluctuation noise set by the measured fractional frequency noise.
On the basis of the measured diffusion noise spectra, we estimate the excess Allan deviation due to diffusion, by integrating the fitted noise spectral density (see Supporting Information).31 In our experimental regime (τA ≫ τD), we have σA,diff(τA) ≈ 0.83·√N (m/M)(τD/τA)1/4, and the total expected instability due to adsorbate diffusion is thus . As Figure 3 demonstrates, this model yields excellent agreement in both the temperature dependency and the magnitude of the experimental data. Contrasted with the predictions of the pure adsorption–desorption model, this provides strong support for a surface kinetics dominated by surface diffusion. Very interestingly and importantly, the combined measurements and analyses have revealed a noise process that has new power laws Sy(ω) ~ ωα with α = −1/2 and instability σA(τA) ~ τAβ with β = −1/4, which to the best of our knowledge have never been documented nor considered in conventional oscillators and clocks (i.e., all known oscillator noise spectra power laws involve an integer exponent α=0, ±1, ±2…).32 The revelation of these new weak power laws is possible because for the first time we are now able to tune a very sensitive VHF NEMS resonator to follow in real time the one-dimensional diffusion of adsorbate. It is important to point out the general character of our diffusion noise analysis, which could straightforwardly be extended by means of numerical simulations to account for the properties of different adsorption sites and/or different coverage regimes.
In conclusion, we have investigated the kinetics and fluctuations of surface adsorbate on a high-Q NEMS resonator vibrating at 190.5 MHz. By measuring and analyzing the temperature-programmed adsorption spectrum and device frequency fluctuations, we have found that adsorbate diffusion can dominate the observed excess noise. The sensitive measurements have also led to the discovery of new power laws of frequency noise in low-dimensional systems. These first measurements of surface adsorbates dynamics and fluctuations using resonant NEMS may have important implications for at least the following fundamental and technological applications: (i) The surface adsorbates-induced noise translates into equivalent mass fluctuations on the device surface; this imposes limits for the achievable sensitivity of frequency-shift based sensors. (ii) Following this study, it has been attempted to control and engineer adsorbates distribution (e.g., concentration gradient) and surface kinetics to enhance NEMS sensors’ functions and performance.33 (iii) The approach of using NEMS to probe submonolayer surface physics may prove to be a useful supplement to the existing surface science tools, particularly when combined with in situ techniques,34 to pursue, for example, quantitative, real-time measurements of mesoscopic processes such as interfacial damping and atomic tribology.35 Further engineering with innovative device geometries and resonant mode shapes can also help to explore nanoscale Chladni figures36 that may be important for molecular-scale biodetection in fluids and other complicated surface phenomena. This study also opens new opportunities for pushing the limits by investigating surfaces of NEMS made of other emerging materials such as ultrathin nanowires,37 nanotubes,38 and atomically thin graphene sheets.39
Supplementary Material
Table 1.
T (K) | N (T) | τD (s) | D (cm2/s) | σA,diff (τA = 1s) |
---|---|---|---|---|
58.0 | 2.19 × 106 | 0.114 | 1.18 × 10−8 | 1.16 × 10−6 |
59.2 | 1.71 × 106 | 0.064 | 2.12 × 10−8 | 8.86 × 10−7 |
60.7 | 1.27 × 106 | 0.055 | 2.44 × 10−8 | 7.36 × 10−7 |
63.4 | 7.69 × 105 | 0.053 | 2.53 × 10−8 | 5.69 × 10−7 |
ACKNOWLEDGMENT
We thank S. Stryker for help in engineering the experimental apparatus. We thank C.A. Zorman and M. Mehregany for custom-made high-quality thin SiC layers. X.L.F. is grateful to M. C. Cross and L. G. Villanueva for helpful discussions, and to Y. Wu for help with the illustrations. We acknowledge the support from DARPA/MTO and SPAWAR under the Grant N66001-02-1-8914.
Footnotes
ASSOCIATED CONTENT
Supporting Information. Experimental system and techniques employed; supporting theoretical and modeling work. This material is available free of charge via the Internet at http://pubs.acs.org.
REFERENCES
- 1.(a) Eigler DM, Schweizer EK. Positioning single atoms with a scanning tunneling microscope. Nature. 1990;344:524–526. [Google Scholar]; (b) Eigler DM, Weiss PS, Schweizer EK, Lang ND. Imaging Xe with a low-temperature scanning tunneling microscope. Phys. Rev. Lett. 1991;66:1189–1192. doi: 10.1103/PhysRevLett.66.1189. [DOI] [PubMed] [Google Scholar]; (c) Markus T, Lutz CP, Hirjibehedin CF, Giessibl FJ, Heinrich AJ. The force needed to move an atom on a surface. Science. 2008;319:1066–1069. doi: 10.1126/science.1150288. [DOI] [PubMed] [Google Scholar]
- 2.Whitesides GM. Self-assembly at all scales. Science. 2002;295:2418–2421. doi: 10.1126/science.1070821. [DOI] [PubMed] [Google Scholar]
- 3.Rothemund PW. Folding DNA to create nanoscale shapes and patterns. Nature. 2006;440:297–302. doi: 10.1038/nature04586. [DOI] [PubMed] [Google Scholar]
- 4.Barth JV, Costantini G, Kern K. Engineering atomic and molecular nanostructures at surfaces. Nature. 2005;437:671–679. doi: 10.1038/nature04166. [DOI] [PubMed] [Google Scholar]
- 5.Bhushan B, Israelachvili JN, Landman U. Nanotribology: friction, wear and lubrication at the atomic scale. Nature. 1995;374:607–616. [Google Scholar]
- 6.(a) Roukes ML. Nanoelectromechanical systems face the future. Phys. World. 2001;14:25–31. [Google Scholar]; (b) Snow ES, Perkins FK, Houser EJ, Badescu SC, Reinecke TL. Chemical detection with a single-walled carbon nanotube capacitor. Science. 2005;307:1942–1945. doi: 10.1126/science.1109128. [DOI] [PubMed] [Google Scholar]; (c) Lavrik N, Sepaniak MJ, Datskos PG. Cantilever transducers as a platform for chemical and biological sensors. Rev. Sci. Instrum. 2004;75:2229–2253. [Google Scholar]
- 7.Buttry DA, Ward MD. Measurement of interfacial processes at electrode surfaces with the electrochemical quartz crystal microbalance. Chem. Rev. 1992;92:1355–1379. [Google Scholar]
- 8.Rodahl M, Höök F, Krozer A, Brzezinski P, Kasemo B. Quartz crystal microbalance setup for frequency and Q-factor measurements in gaseous and liquid environments. Rev. Sci. Instrum. 1995;66:3924–3930. [Google Scholar]
- 9.Yang YT, Callegari C, Feng XL, Ekinci KL, Roukes ML. Zeptogram-scale nanomechanical mass sensing. Nano Lett. 2006;6:583–586. doi: 10.1021/nl052134m. [DOI] [PubMed] [Google Scholar]
- 10.(a) Lassagne B, Garcia-Sanchez D, Aguasca A, Bachtold A. Ultrasensitive mass sensing with a nanotube electromechanical resonator. Nano Lett. 2008;8:3735–3738. doi: 10.1021/nl801982v. [DOI] [PubMed] [Google Scholar]; (b) Chiu HY, Hung P, Postma HWCh, Bockrath M. Atomic-scale mass sensing using carbon nano-tube resonators. Nano Lett. 2008;8:4342–4346. doi: 10.1021/nl802181c. [DOI] [PubMed] [Google Scholar]
- 11.Jensen K, Kim K, Zettl A. An atomic-resolution nanomechanical mass sensor. Nat. Nanotechnol. 2008;3:533–537. doi: 10.1038/nnano.2008.200. [DOI] [PubMed] [Google Scholar]
- 12.Bruch LW, Diehl RD, Venables JA. Rev. Mod. Phys. 2007;79:1381–1454. [Google Scholar]
- 13.Huang XMH, Feng XL, Zorman CA, Mehregany M, Roukes ML. New J. Phys. 2005;7:247. [Google Scholar]
- 14.McCafferty E, Wightman JP. An X-ray photoelectron spectroscopy sputter profile study of the native air-formed oxide film on titanium. Appl. Surf. Sci. 1999;143:92–100. [Google Scholar]
- 15.Diebold U. The surface science of titanium dioxide. Surf. Sci. Rep. 2003;48:53–229. [Google Scholar]
- 16.(a) Bikondoa O, Pang CL, Ithnin R, Muryn CA, Onishi H, Thornton G. Direct visualization of defect-mediated dissociation of water on TiO2 (110) Nat. Mater. 2006;5:189–192. [Google Scholar]; (b) He YB, Tilocca A, Dulub O, Selloni A, Diebold U. Local ordering and electronic signatures of submonolayer water on anatase TiO2 (101) Nat. Mater. 2009;8:585–589. doi: 10.1038/nmat2466. [DOI] [PubMed] [Google Scholar]; (c) Zhang Z, Bondarchuk O, Kay DB, White JM, Dohnalek Z. Imaging water dissociation on TiO2 (110): evidence for inequivalent Geminate OH groups. J. Phys. Chem. B. 2006;110:21840–21845. doi: 10.1021/jp063619h. [DOI] [PubMed] [Google Scholar]
- 17.Yang YT. Ph. D. Thesis. California Institute of Technology; Pasadena, CA: 2007. Phase noise of nanoelectromechanical systems. [Google Scholar]
- 18.Hudson JB. Surface Science: An Introduction. J. Wiley & Sons; New York: 1998. [Google Scholar]
- 19.(a) Zangwill A. Physics at Surfaces. Cambridge University Press; New York: 1988. [Google Scholar]; (b) Oura K, Lifshits VG, Saranin AA, Zotov AV, Katayama M. Surface Science: An Introduction. Springer; Berlin: 2003. [Google Scholar]
- 20.Ibach H. Physics of Surfaces and Interfaces. Springer; Berlin: 2006. [Google Scholar]
- 21.(a) Krim J, Dash JG, Suzanne J. Triple-point wetting of light molecular gases on Au (111) surfaces. Phys. Rev. Lett. 1984;52:640–643. [Google Scholar]; (b) Cheng E, Cole MW, Dupont-Roc J, Saam WF, Treiner J. Novel wetting behavior in quantum films. Rev. Mod. Phys. 1993;65:557–567. [Google Scholar]
- 22.Bruch LW, Cole MW, Zaremba E. Physical Adsorption: Forces and Phenomena. Oxford University Press; New York: 1997. [Google Scholar]
- 23.Kritzenberger J, Gaede HC, Shore JS, Pine A, Bell AT. 129Xe NMR study of TiO2 (anatase)-supported V2O5 catalysts. J. Phys. Chem. 1994;98:10173–10179. [Google Scholar]
- 24.Rittner F, Paschek D, Boddenberg B. Simulation studies of the adsorption of xenon on the (110) face of rutile. Langmuir. 1995;11:3097–3102. [Google Scholar]
- 25.Meixner DL, George SM. Surface diffusion of xenon on Pt (111) J. Chem. Phys. 1993;98:9115–9125. [Google Scholar]
- 26.(a) Bienfait M, Venables JA. Kinetics of adsorption and desorption using Auger electron spectroscopy: application to xenon covered (0001) graphite. Surf. Sci. 1977;64:425–436. [Google Scholar]; (b) Ulbricht H, Zacharia R, Cindir N, Hertel T. Thermal desorption of gases and solvents from graphite and carbon nanotube surfaces. Carbon. 2006;44:2931–2942. [Google Scholar]
- 27.Thomas P, Gray J, Zhu XD, Fong CY. Surface diffusion of Xe on Nb(110) Chem. Phys. Lett. 2003;381:376–380. [Google Scholar]
- 28.Allan DW. Time and frequency (time-domain) characterization, estimation and prediction of precision clocks and oscillators. IEEE Trans. Ultrason. Ferroelect. Freq. Control. 1987;34:647–654. doi: 10.1109/t-uffc.1987.26997. [DOI] [PubMed] [Google Scholar]
- 29.(a) Yong YK, Vig JR. Resonator surface contamination-a cause of frequency fluctuations? IEEE Trans. Ultrason. Ferroelect. Freq. Control. 1989;36:452–458. doi: 10.1109/58.31783. [DOI] [PubMed] [Google Scholar]; (b) Yong YK, Vig JR. Modeling resonator frequency fluctuations induced by adsorbing and desorbing surface molecules. IEEE Trans. Ultrason. Ferroelect. Freq. Control. 1990;37:543–550. doi: 10.1109/58.63111. [DOI] [PubMed] [Google Scholar]
- 30.Gradshteyn IS, Ryzhik IM. In: Table of Integrals, Series and Products. 7th ed. Jeffrey A, Zwillinger D, editors. Elsevier; Amsterdam: 2007. [Google Scholar]
- 31.(a) Rutman J. Characterization of phase and frequency instabilities in precision frequency sources: fifty years of progress. Proc. IEEE. 1978;66:1048–1075. [Google Scholar]; (b) Egan WF. Frequency Synthesis by Phase Lock. 2nd ed. John Wiley & Sons; New York: 2000. [Google Scholar]
- 32.(a) Sullivan DB, Allan DW, Howe DA, Walls FL, editors. Characterization of Clocks and Oscillators; NIST Technical Note 1337. U. S. Government Printing Office; Washington, DC: 1990. [Google Scholar]; (b) Definitions of physical quantities for fundamental frequency and time metrology–random instabilities; IEEE Standard 1139–1999. IEEE Press; New York: 1999. [Google Scholar]
- 33.Myers EB, et al. 2011 Unpublished work. [Google Scholar]
- 34.Horch S, Zeppenfeld P, Comsa G. A scanning tunneling microscopy study of the adsorption of Xe on Pt(111) up to one monolayer. Appl. Phys. A. 1995;60:147–153. [Google Scholar]
- 35.Krim J, Solina DH, Chiarello R. Nanotribology of a Kr monolayer: a quartz-crystal microbalance study of atomic-scale friction. Phys. Rev. Lett. 1991;66:181–184. doi: 10.1103/PhysRevLett.66.181. [DOI] [PubMed] [Google Scholar]
- 36.Dorrestijn M, Bietsch A, Acikalin T, Raman A, Hegner M, Meyer E, Gerber Ch. Chladni figures revisited based on nanomechanics. Phys. Rev. Lett. 2007;98 doi: 10.1103/PhysRevLett.98.026102. No. 026102. [DOI] [PubMed] [Google Scholar]
- 37.He RR, Feng XL, Roukes ML, Yang PD. Self-transducing silicon nanowire electromechanical systems at room temperature. Nano Lett. 2008;8:1756–1761. doi: 10.1021/nl801071w. [DOI] [PubMed] [Google Scholar]
- 38.Wang ZH, Wei J, Morse P, Dash JG, Vilches OE, Cobden DH. Phase transitions of adsorbed atoms on the surface of a carbon nanotube. Science. 2010;327:552–555. doi: 10.1126/science.1182507. [DOI] [PubMed] [Google Scholar]
- 39.Chen CY, Rosenblatt S, Bolotin KI, Kalb W, Kim P, Kymissis I, Stormer HL, Heinz TF, Hone J. Performance of monolayer graphene nanomechanical resonators with electrical readout. Nat. Nanotechnol. 2009;4:861–867. doi: 10.1038/nnano.2009.267. [DOI] [PubMed] [Google Scholar]
Associated Data
This section collects any data citations, data availability statements, or supplementary materials included in this article.