Table 3.

Correlation, bias and precision across different ranges of CLCR

  r ( P -value) Bias +/− precision (ml/min/1.73 m 2 )
CLCR < 90 ml/min/1.73 m2 (n = 28)
175 eGFR
0.223 (0.253)
−12.6 +/− 35.2
CG CLCR
0.278 (0.152)
−15.9 +/− 37.2
CKD-EPI eGFR
0.351 (0.067)
−11.1 +/− 23.2
CLCR 90–119 ml/min/1.73 m2 (n = 23)
175 eGFR
0.065 (0.767)
10.5 +/− 44.4
CG CLCR
0.066 (0.763)
−0.93 +/− 43.9
CKD-EPI eGFR
−0.067 (0.760)
14.8 +/− 22.8
CLCR 120–149 ml/min/1.73 m2 (n = 23)
175 eGFR
0.047 (0.832)
22.7 +/− 26.1
CG CLCR
0.369 (0.083)
6.62 +/− 23.9
CKD-EPI eGFR
0.347 (0.104)
29.2 +/− 10.8
CLCR ≥ 150 ml/min/1.73 m2 (n = 36)
175 eGFR
0.427 (0.009)
36.1 +/− 31.3
CG CLCR
0.399 (0.016)
27.8 +/− 27.2
CKD-EPI eGFR 0.460 (0.005) 55.0 +/− 20.9

CLCR = 8-hr Creatinine Clearance, CG CLCR = Cockcroft-Gault Creatinine Clearance, 175 eGFR = Abbreviated Modification of Diet in Renal Disease 175 formula, CKD-EPI eGFR = Chronic Kidney Disease Epidemiology Collaboration Equation, r = Pearson correlation coefficient.