APPENDIX 2.

Stroke Imaging Protocol

Standardized MRI Protocol
  • Diffusion-weighted imaging

  • Gradient-recalled echo or susceptibility-weighted imaging

  • T2-weighted FLAIR

  • Contrast-enhanced MR angiography (first injection)

  • Dynamic susceptibility contrast perfusion MRI (second injection)

  • Contrast-enhanced T1-weighted sequence

General Parameter Recommendations
  • Minimum slice thickness 5 mm

  • Contrast-enhanced MR angiography injection: 0.05 mmol at 2 mL/s

  • Dynamic susceptibility contrast perfusion MRI injection: 0.5 mmol at 5 mL/s

Alternative Protocol
  • Time-of-flight MR angiography and arterial spin labeling in combination