Table 3.

Results of the survival model predicting risk of development of visual field loss excluding longitudinal rim area measurements

Parameter Coefficient 95% CI P Hazard ratio
Age, per decade older 0.008 −0.226 – 0.243 0.944 1.01
Race, Black 0.75 0.19 – 1.31 0.009 2.12
IOP, per 1mmHg higher 0.0816 0.0082 – 0.1550 0.029 1.09
CCT, per 100µm thinner 0.98 0.24 – 1.73 0.009 2.66
PSD, per 0.1dB higher 0.12 0.10 – 0.14 <0.001 1.13
Disc Area, per 0.1mm2
larger
0.005 −0.046 – 0.056 0.849 1.01

IOP – intraocular pressure; CCT – central corneal thickness; PSD – pattern standard deviation; CI – confidence interval