Table 1.
τ1 (ps) relative amplitude | τ2 (ps) relative amplitude | τ3 (ps) relative amplitude | kS0 (ps−1) | kET (ps−1) | |
---|---|---|---|---|---|
wt MR | 0.26 ± 0.05 47 ± 12% | 3.3 ± 0.2 33 ± 1% | 16.6 ± 0.7 19 ± 1% | 0.23 ± 0.01 | 0.10 ± 0.03 |
wt MR -NADH4 | 0.26 ± 0.03 63 ± 11% | 3.2 ± 0.2 27 ± 1% | 19.9 ± 1.3 10 ± 1% | 0.33 ± 0.02 | |
V108L | - | 3.9 ± 0.1 58 ± 1% | 22.3 ± 0.8 42 ± 1% | 0.09 ± 0.01 | 0.07 ± 0.01 |
V108L-NADH4 | 0.24 ± 0.03 48 ± 10% | 4.5 ± 0.1 33 ± 1% | 26.2 ± 0.9 19 ± 1% | 0.15 ± 0.01 | |
V108A | - | 3.0 ± 0.1 70 ± 2% | 17.0 ± 1.0 30 ± 2% | 0.14 ± 0.01 | 0.11 ± 0.05 |
V108A-NADH4 | 0.47 ± 0.08 53 ± 8% | 4.4 ± 0.4 40 ± 2% | 27.3 ± 8.5 8 ± 2% | 0.25 ± 0.05 | |
W106A | - | 2.5 ± 0.3 81 ± 8% | 8.1 ± 1.9 19 ± 9% | 0.28 ± 0.06 | 0.25 ± 0.08 |
W106A - NADH4 | 0.34 ± 0.05 59 ± 9% | 4.0 ± 0.4 43 ± 1% | - | 0.53 ± 0.04 | |
PETNR | - | 1.8 ± 0.4 40 ± 4% | 22.4 ± 1.9 60 ± 2% | 0.07 ± 0.01 | |
PETNR - NADH4 | 0.77 ± 0.11 79 ± 8% | - | 8.5 ± 1.2 21 ± 2% | 0.41 ± 0.06 | 0.34 ± 0.07 |
PETNR - NADPH4 | 0.63 ± 0.08 84 ± 8% | - | 7.8 ± 1.1 16 ± 2% | 0.56 ± 0.09 | 0.49 ± 0.09 |
Errors quoted on the lifetimes and relative amplitudes are those from the fitting procedure, it should be noted that the time resolution of the system is on the order of 200 fs, and this is the value used for error propagation to the rate values if the error on the fit is smaller than this.