Skip to main content
. 2013 Nov 20;2013:610297. doi: 10.1155/2013/610297

Table 1.

Comparison of the estimated FWER and power for the resampling-based multiple testing procedures with FWER controlled at 5%.

(mm 0)/m mt.maxT mt.minP ss.maxT ss.minP sd.maxT sd.minP
FWER 0.10 0.00 0.00 0.18 0.53 0.14 0.53
0.25 0.00 0.00 0.07 0.19 0.05 0.19
0.50 0.00 0.00 0.02 0.06 0.02 0.07
0.75 0.00 0.00 0.01 0.02 0.01 0.02
0.90 0.00 0.00 0.00 0.01 0.00 0.01

Power 0.10 0.00 0.00 0.11 0.27 0.09 0.30
0.25 0.00 0.00 0.12 0.32 0.11 0.32
0.50 0.00 0.00 0.10 0.28 0.09 0.29
0.75 0.00 0.00 0.11 0.27 0.10 0.28
0.90 0.00 0.00 0.11 0.28 0.11 0.28

mt.maxT: permutation single-step maxT procedure; mt.minP: permutation single-step minP procedure; ss.maxT: bootstrap single-step maxT procedure; ss.minP: bootstrap single-step minP procedure; sd.maxT: bootstrap step-down maxT procedure; sd.minP: bootstrap step-down minP procedure.