Table 5.
Anodic polarization current and potential at monitoring points.
| Monitoring Point | W1 | W2 | W3 | W4 |
|---|---|---|---|---|
| Eoc after wetting | −60 mV | −75 mV | −95 mV | −132 mV |
| Eoc after drying | 53 mV | 58 mV | 66 mV | 26 mV |
| IAPC after wetting | −226 nA | −235 nA | −528 nA | −259 nA |
| IAPC after drying | 40.78 nA | 31.26 nA | 34.84 nA | 33.88 nA |