Summary of datasets.

Dataset Experiment Subject Number of conditions Condition duration (seconds) Number of repetitions per run (or run set) Number of runs (or run sets) Scanner RF coil Voxel size (mm) TR (seconds) TE (ms) Flip angle (deg) Volume dimensions Number of volumes per run Total number of runs Physiological data collected?
1 A S1 69 3 1 5 3T1 N8 2.5 1.323751 29.7 71 64 × 64 × 21 270 10 No
2 A S2 69 3 1 5 3T1 N2 2.5 1.323751 29.7 71 64 × 64 × 21 270 10 No
3 A S3 69 3 1 5 3T1 N2 2.5 1.323751 29.7 71 64 × 64 × 21 270 10 No
4 B S3 156 3 1 3 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 300 12 No
5 B S2 156 3 1 3 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 300 12 No
6 B S4 156 3 1 3 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 300 12 No
7 C S5 104 3.5 1 7 CNI N32 2 1.985626 31 77 80 × 80 × 26 140 14 No
8 C S4 104 3.5 1 7 CNI N32 2 1.985626 31 77 80 × 80 × 26 140 14 No
9 D S2 69 3 1 5 CNI N32 1.8 1.605242 35 73 70 × 70 × 20 225 10 No
10 E S4 35 3 1 10 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 270 10 No
11 F S3 9 3 2 15 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 150 15 No
12 G S6 69 1 2 6 3T2 N8 2.5 1.323751 28.7 77 64 × 64 × 20 252 12 No
13 G S7 69 1 2 6 3T2 N8 2.5 1.323751 28.7 77 64 × 64 × 20 252 12 No
14 H S2 20 3 1 4 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 162 4 Yes
15 H S3 20 3 1 4 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 162 4 Yes
16 I S8 9 3 2 4 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 150 4 Yes
17 I S9 9 3 2 4 CNI N32 2.5 1.337702 28 68 64 × 64 × 22 150 4 Yes
18 J S4 81 5 1 6 CNI N16 2 2.006553 31 77 80 × 80 × 26 156 12 Yes
19 J S10 81 5 1 6 CNI N16 2 2.006553 31 77 80 × 80 × 26 156 12 Yes
20 K S11 20 3 1 4 CNI N32 2 2.006553 31 77 80 × 80 × 26 108 4 Yes
21 K S12 20 3 1 4 CNI N32 2 2.006553 31 77 80 × 80 × 26 108 4 Yes

3T1, Lucas Center at Stanford University, 3T GE Signa HDX scanner; 3T2, Lucas Center at Stanford University, 3T GE Signa MR750 scanner; CNI, Stanford Center for Neurobiological Imaging, 3T GE Signa MR750 scanner; N2, Nova quadrature RF coil; N8, Nova 8-channel RF coil; N16, Nova 16-channel visual array RF coil; N32, Nova 32-channel RF coil.

Additional notes: All datasets used a T2*-weighted, single-shot, gradient-echo pulse sequence, either spiral-trajectory (3T1, 3T2) or echo-planar imaging (CNI). Experiment I was identical to experiment F except that physiological data were collected and fewer runs were collected. Experiment K was identical to experiment H except for differences in pulse sequence parameters (voxel size, TR, TE, flip angle).